Facts
Show comparison list
Nitrile
Material: Nitrile
Properties
- 100% nitrile
- disposable protective glove
- free from vulcanisation accelerators
- cleaned of production residues with deionised water
- low endotoxin load
- gamma irradiated, min. 25 kGy
- hand specific
- colour neon green
- textured glove palm and finger inside
- cuffs with beaded edge
Advantages
- protective glove against hazardous chemicals (protection type B) for three different classes of substances such as inorganic bases, peroxides, aldehydes: K Sodium hydroxide 40%; P Hydrogen peroxide 30%; T Formaldehyde 37%
- protective glove against micro-organisms such as viruses
- Acceptable Quality Limit of the highest performance level 3 (1 up to 3)
- meets the requirements and physical properties for medical gloves for single-use (EN 455-2:2015)
- low extractable and leachable ionic loads
- manufactured in an ISO cleanroom of cleanliness class 5 and certified by the National Environmental Balancing Bureau (NEBB)
- triple packed to avoid cross contamination
Application
- microbiologically and particulate controlled cleanrooms
- laboratories working with certain hazardous chemicals and/or microorganisms
- sterile production environments
- aseptic packaging areas
- suitable as an under-glove for the double gloving procedure
Product recommendation based on cleanroom classes
Air cleanliness class EN ISO 14644-1
particulate monitored areas
Hygiene zones according to GMP
microbiological monitored areas
PPE
Personal protective equipment
Regulation (EU) 2016/425
A one-to-one classification of cleanroom gloves to a cleanroom class according to ISO 14644-1 is not possible. Recommendations can only be made based on cleanroom specific requirements, e.g. "abrasion resistance" or "particle emission". In the VDI guideline 2083 Part 9.2 the user can find additional information.
Technical data
Unit of measurement | Value | Test method | ||
Material | 100% Nitrile | |||
Perforation-free1 AQL value as defined in ISO 2859-1 for attribute testing on samples | AQL1 |
0.65 Level 3 Inspection level G1 | EN ISO 374-2:2019 | |
Tear resistance |
before ageing after accelerated ageing | N min./typical |
6.0/n. s. n. s./n. s. | EN 455-2:2015 |
Extreme elongation |
before ageing after accelerated ageing |
% min. |
n. s. n. s. | EN 455-2:2015 |
Dimensions nominal single wall thickness |
middle finger glove palm cuff |
mm ± 0.02 mm |
0.16 0.14 0.09 | EN 455-2:2015 |
Length | mm min./typical | 290/300 | EN ISO 21420:2020 | |
Size/palm width nominal (+/- 5 mm) |
6 6½ 7 7½ 8 8½ 9 10 |
mm +/- 0.02 mm | n. s. |
EN ISO 21420:2020 EN 455-2:2015 |
Permeation performance against chemicals | Type B |
EN ISO 374-1:2016 + A1:2018 | ||
Protection against microbiological pathogens viruses or bacteria or fungi |
passed viruses | EN ISO 374-5:2016 | ||
Extractable particles | ≥ 0.5 µm |
nominal number/cm2 | 1,800 | IEST-RP-CC005.4 |
Extractable substances | Ions Ammonium (NH4+) Bromide (Br-) Calcium (Ca+) Chloride (ClO2-) Copper (Cu+) Fluoride (F-) Iron (Fe+) Lithium (Li+) Magnesium (Mg+) Nitrate (NO3-) Nitrite (NO2-) Phosphate (PO43-) Potassium (K+) Sodium (Na+) Sulphate (SO42-) Zinc (Zn+) |
µm/cm2 Spezifikation n. s. n. s. n. s. n. s. n. s. n. s. n. s. n. s. n. s. n. s. n. s. n. s. n. s. n. s. n. s. n. s. |
µm/cm2 Typical value 0.014 n. d. 0.522 0.110 n. d. n. d. n. s. n. s. n. d. 0.318 n. d. n. d. 0.034 0.006 0.021 n. s. | IEST-RP-CC005.4 |
Endotoxins detected by LAL-test, kinetic turbidimetric |
Endotoxin units (EU) per pair | < 20 EU | EN 455-3:2015 | |
Silicones, amides, Di-n-octyl phthalate (DNOP) | n. s. |
IEST-RP-CC005.4 FTIR test procedure | ||
Powder residue values |
mg/gloves typical (max. 2 mg) |
powder-free < 2 mg | ASTM D6124 | |
Biocompatibility | n. s. |
ISO 10993-10:2010 | ||
Skin sensitization | passed | ISO 10993-10:2021 | ||
Gamma irradiated Sterility assurance level (SAL) | 10-6 | according EN ISO 11137-1:2015 | ||
Non volatile residues (NVR) | mg/g | n. s. | IEST-RP-CC005.4 | |
ESD properties surface resistance contact resistance charge decay electrostatic properties (design + material requirements) |
n. s. | EN 1149-1:2006 EN 1149-2:1997 EN 1149-3:2004 EN 1149-5 | ||
Permeation resistance of medical gloves for chemotherapeutics | not applicable | ASTM D6978-05(2019) | ||
Shelf life from date of manufacture | three (3) years |
when stored properly | ||
PU |
20 pairs packed in pairs in a folded PE sheet (Left/Right) and sealed PE bag, in a PE outer bag, lined carton | |||
Carton quantity |
200 pairs 20 PE outer bags of 10 pairs | |||
n. s. = not specified n. d. = not detected |