Facts
Show comparison list
Nitrile
Material: Nitrile
Properties
- 100% nitrile
- sterile
- packed in pairs in foil
- hand specific
Advantages
- very good surface cleanliness
- extra long, 60 cm
- high abrasion resistance
- high permeation time with disinfectants
- tested with cytostatics
Application
- sterile production / aseptic filling
- for cleaning / disinfection with disinfectants and biocides
- for the production of cytostatics
- for heavy mechanical stress
Product recommendation based on cleanroom classes
Air cleanliness class EN ISO 14644-1
particulate monitored areas
Hygiene zones according to GMP
microbiological monitored areas
PPE
Personal protective equipment
Regulation (EU) 2016/425
A one-to-one classification of cleanroom gloves to a cleanroom class according to ISO 14644-1 is not possible. Recommendations can only be made based on cleanroom specific requirements, e.g. "abrasion resistance" or "particle emission". In the VDI guideline 2083 Part 9.2 the user can find additional information.
Technical data
Unit of measurement | Value | Test method | ||
Material | 100% nitrile | |||
Perforation-free 1AQL value as defined in ISO 2859-1 for attribute testing on samples | AQL1 | 0.65 Level 3 | ISO 374-2:2019 | |
Tear resistance |
before ageing after accelerated ageing | N min./typical |
≥ 6.0/11.0 ≥ 6.0/9.0 |
EN 455-2:2015 + ASTM D412-15a ASTM D573-04(2015) |
Extreme elongation |
before ageing after accelerated ageing |
% min. |
≥ 500 ≥ 400 |
EN 455-2:2015 + ASTM D412-15a ASTM D573-04(2015) |
Dimensions nominal single wall thickness |
middle finger palm cuff | mm |
0.20 0.17 0.11 | ASTM D3767-03(2014) |
Length from the tip of the middle finger to the edge of the cuff | mm min./typical | 580 / 600 | EN ISO 21420:2020 | |
Size/palm width nominal (+/- 5 mm) |
5½ 6 6½ 7 7½ 8 8½ 9 10 | mm | n.s. | EN ISO 21420:2020 |
Size/Hand circumference nominal |
5½ 6 6½ 7 7½ 8 8½ 9 10 | mm |
140 152 165 178 191 203 216 229 254 | EN ISO 21420:2020 |
Extractable particles | ≥ 0.5 µm |
fixed typical number/cm2 | < 1,200 1,000 | IEST-RP-CC005.4 |
Extractable substances | Ions Ammonium (NH4+) Bromide (Br-) Calcium (Ca+) Chloride (ClO2-) Copper (Cu+) Fluoride (F-) Iron (Fe+) Lithium (Li+) Magnesium (Mg+) Nitrate (NO3-) Nitrite (NO2-) Phosphate (PO43-) Potassium (K+) Sodium (Na+) Sulphate (SO42-) Zinc (Zn+) |
µg/cm2 specification 0.050 0.030 0.350 0.200 n.s. 0.010 n.s. 0.010 0.030 0.030 0.030 0.050 0.050 0.050 n.s. |
µg/cm2 typical value 0.015 < 0.008 0.200 0.090 n.s. < 0.008 n.s. < 0.008 0.020 < 0.008 < 0.008 0.020 0.011 0.008 n.s. | IEST-RP-CC005.4 |
Gamma sterilized Sterility assurance level (SAL) | 10-6 |
according to ANSI/ AAMI/ EN ISO 11137:2015 | ||
Silicones, amides,Di-n-octyl phthalate (DNOP) | not detectable |
IEST-RP-CC005.4 FTIR test procedure | ||
Vulcanisation accelerators | free | produced without thiazoles and thiurams | ||
Non Volatile Residues (NVR) | mg/g | ≤ 30 | IEST-RP-CC005.4 | |
Endotoxins kinetic turbidimetric LAL test) |
Endotoxin units (EU) per pair | < 20 | EN 455-3:2015 | |
Permeation resistance of medical gloves for chemotherapeutics | compliant | ASTM D6978-05 | ||
ESD behaviour surface resistance contact resistance charge decay electrostatic properties (construction + material requirements) | n.s. | EN 1149-1:2006 EN 1149-2:1997 EN 1149-3:2004 EN 1149-5 | ||
PU |
20 pairs pairwise packed in a tear-open pouch, in a heat-sealed sterile PE-bag | |||
Cardboard quantity |
100 pairs 5 PE-bags in a sealed outer PE-bag |