+++ 04.11.2024 - 11:21 Uhr: The sales units for selected products will be optimised shortly. If you have any questions about this, please call your contact person in the sales department. +++

Skip to main content

SHIELDskin XTREME™ Bright Latex 300 DI+

Latex glove

To this glove in our product portfolio

Facts


Show comparison list
Surface cleanliness
Grip
Elongation
Endotoxin pollution
Ion-free
Cytostatics compatible
Chemical protection
sterile
textured
hand specific

Latex

SHIELDskin XTREME™ Bright Latex 300 DI+, Art.-No. 3801

Material: Latex

Properties

  • 100% latex
  • powder-free
  • packed in bags
  • ambidextrous

Advantages

  • satisfactory surface cleanliness
  • very good form fit
  • very high elasticity
  • very high tear resistance
  • good grip

Application

  • for normal process requirements
  • for heavy mechanical stress

Product recommen­dation based on cleanroom classes

Air cleanliness class EN ISO 14644-1
particulate monitored areas

123456789low dust

Hygiene zones according to GMP
microbiological monitored areas

ABCDE

PPE

Personal protective equipment
Regulation (EU) 2016/425

Cat. ICat. IICat. IIInot aplicable

A one-to-one classification of cleanroom gloves to a cleanroom class according to ISO 14644-1 is not possible. Recommendations can only be made based on cleanroom specific requirements, e.g. "abrasion resistance" or "particle emission". In the VDI guideline 2083 Part 9.2 the user can find additional information.

Technical data

    Unit of measurementValueTest method
Material     100% Latex  
Perforation free1
AQL value as defined in ISO 2859-1
for attribute testing on samples
  AQL1 1.5 Level 2 ISO 374-2:2019
Tear resistance before ageing
after accelerated ageing
N min./typical 9.0/9.0
6.0/9.0
EN 455-2:2015 + ASTM D412-15a
ASTM D573-04(2015)
Extreme elongation before ageing
after accelerated ageing
% min.
700
500
EN 455-2:2015 + ASTM D412-15a
ASTM D573-04(2015)
Dimensions
nominal single wall thickness
middle finger
palm
cuff
mm 0.16
0.14
0.10
ASTM D3767-03(2014)
Length   mm min./typical 300/305 EN 455-2:2015
Size/palm size
nominal (+/- 5 mm)
XS / 6
S / 7
M / 8
L / 9
XL / 10
mm ≤ 75
85
95
106
≤ 116
EN 455-2:2015
Size/Hand circumference
nominal
XS / 6
S / 7
M / 8
L / 9
XL / 10
mm
152
178
203
229
254
EN ISO 21420:2020
Biocompatibility     proved Primary Skin Irritation Tests +
Dermal Sensitization Test
according to ASTM F720-13
Powder free   µg/gloves approx.
1.0 – max. 2.0
ISO 21171:2006
Extractable particles
defined
typical
number/cm2 > 0.5 µm 1,200
900
 
Extractable substances
Ions

Ammonium (NH4+)
Bromide (Br-)
Calcium (Ca+)
Chloride (ClO2-)
Copper (Cu+)
Fluoride (F-)
Iron (Fe+)
Lithium (Li+)
Magnesium (Mg+)
Nitrate (NO3-)
Nitrite (NO2-)
Phosphate (PO43-)
Potassium (K+)
Sodium (Na+)
Sulphate (SO42-)
Zinc (Zn+)
µg/cm2
specific
0.050
0.030
0.100
0.750
n.s.
0.010
n.s.
n.s.
0.010
0.400
0.050
0.050
0.050
0.050
0.100
n.s.
µg/cm2
typical
0.015
<0.008
0.080
0.370
n.s.
<0.008
n.s.
n.s.
<0.008
0.250
<0.008
<0.008
0.020
0.020
0.035
n.s.
IEST-RP-CC005.4
Non-volatile residues (NVR)   mg/g ≤ 30 IEST-RP-CC005.4
Endotoxins (maximum)   Endotoxin units (EU)
per pair
n.s. Kinetic turbidimetric
LAL test method
ESD behaviour
Surface resistance
Transit resistance
Charges depletion
Electrostatic properties
(construction + material requirements)
    n.s.
EN 1149-1:2006
EN 1149-2:1997
EN 1149-3:2004
EN 1149-5
PU     100 pieces
flat packed
in PE inner bag
 
Carton quantity     1,000 pieces
10 bags of 100 pieces
in PE outer bag
 

The manufacturer's technical data listed above are typical values at the time of publication. They are not specifications. All data are without guarantee, changes are possible without prior notice.

To top