Facts
Show comparison list
Surface cleanliness
Grip
Elongation
Endotoxin pollution
Ion-free
Cytostatics compatible
Chemical protection
sterile
textured
hand specific
Latex
Kimtech™ G3 Sterile Latex, Art.-No. 3509
Material: Latex
Properties
- 100% latex
- sterile
- smooth – double dressing suitable
- packed in pairs in foil
- hand specific
Advantages
- satisfactory surface cleanliness
- very good form fit
- very high elasticity
- very high tear resistance
Application
- sterile production / aseptic filling
- for heavy mechanical stress
Product recommendation based on cleanroom classes
Air cleanliness class EN ISO 14644-1
particulate monitored areas
Hygiene zones according to GMP
microbiological monitored areas
PPE
Personal protective equipment
Regulation (EU) 2016/425
A one-to-one classification of cleanroom gloves to a cleanroom class according to ISO 14644-1 is not possible. Recommendations can only be made based on cleanroom specific requirements, e.g. "abrasion resistance" or "particle emission". In the VDI guideline 2083 Part 9.2 the user can find additional information.
Technical data
Unit of measurement | Value | Test method | ||
Material | 100% Latex | |||
Perforation-free1 AQL value as defined in ISO 2859-1 for attribute testing on samples | AQL1 | 1.5 | ASTM D5151 + EN 374-2 | |
Tear resistance |
before ageing after accelerated ageing | MPa, nominal |
28 27 | ASTM D412 + ASTM D573 |
Extreme extensibility |
before ageing after accelerated ageing |
%, nominal |
880 900 | ASTM D412 + ASTM D573 |
Dimensions nominal single wall thickness |
middle finger hand surface cuff | mm |
0.22 0.20 0.14 | ASTM D3577 + EN 455-2:2015 |
Length |
mm " |
305 12 | ||
Size/palm width |
6 6½ 7 7½ 8 8½ 9 10 | mm |
77 83 89 95 102 108 114 130 | ASTM D3577 + EN 455-2:2015 |
Biocompatibility | n.s. |
Primary Skin Irritation Tests + Dermal Sensitization Test according to ASTM F720-13 | ||
Extractable particles | > 0.5 µm | number/cm2 | max. 1,500 | IEST-RP-CC005 |
Extractable substances | Ions Ammonium (NH4+) Bromide (Br-) Calcium (Ca+) Chloride (ClO2-) Copper (Cu+) Fluoride (F-) Iron (Fe+) Lithium (Li+) Magnesium (Mg+) Nitrate (NO3-) Nitrite (NO2-) Phosphate (PO43-) Potassium (K+) Sodium (Na+) Sulphate (SO42-) Zinc (Zn+) |
µm/cm2 specification n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. |
µm/cm2 typical value n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. | IEST-RP-CC005.4 |
Endotoxins (maximum) | Endotoxin units (EU) | (EU) per pair | 20 |
Kinetic turbidimetric LAL test method |
Silicones, amides,Di-n-octyl phthalate (DNOP) | not detectable |
IEST-RP-CC005.4 FTIR measuring method | ||
Non Volatile Residues (NVR) | µg/g | n.s. | IEST-RP-CC005.4 | |
Aqueous extractable proteins in latex | µg/g | max. 50 | ASTM D5712 + EN ISO 21420:2020 | |
Electrostatic behaviour | n.s. |
EN 1149-5:2003 | ||
PU |
20 pairs flat pairwise packed in double PE-bags | |||
Carton quantity |
200 pairs, 10 bags of 20 pairs |