The validated sterile version of the series 300, a polyester cellulose non-woven wipe, is versatile, both in microbiological controlled zones and in purely particle controlled areas. Despite the non-woven construction, the wipe is characterised by a certain abrasion and tear resistance (even when damp).
The cloth of the wipes combines the different strengths of cellulose (➜ absorbency) and polyester fibre (➜ abrasion resistance) and is therefore also a happy medium in terms of costs. The hydro-entangled non-woven fabric is, in direct comparison to the series 302, not quite as low in particles and fibres.
Facts
Polyester-cellulose
Non-woven, 45% PES / 55% CEL, hydroentangled, validated sterile
Properties
- 45% polyester / 55% cellulose
- hydroentangled non-woven fabric
- validated sterile
- low particle and fibre emission
- relatively abrasion resistant
- special twill-textured surface
- good absorptive capacity
- double bag packing
Advantages
- good chemical compatibility with different solvents and cleaning agents
- multipurpose
- cost effective
Applications
- all-purpose wipe
- absorption of liquids and spills
- suitable for cleaning tools
- workplace cleaning – especially for smooth surfaces
Product recommendation based on cleanroom classes
Of course, cleanroom wipes used in ISO 5 can also be used in ISO 9, but in this case the economic efficiency and usefulness should be considered.
A 1 to 1 allocation of cleanroom wipes to an air cleanliness class according to ISO 14644-1 is not possible. Recommendations can only be made on the basis of special properties relevant from a cleanroom technical point of view, such as "abrasion resistance" or "particle emission". Users can find further information on this in VDI Guideline 2083 Part 9.2.
Technical data
Properties | Unit of measurement | Value | Test method | |
---|---|---|---|---|
Material | 45% PES / 55% CEL | |||
Edge processing | cold cut | |||
Mass per unit area | g/m2 | 68 | ||
Thickness | mm | 0.30 | ||
Absorptive capacity (Ai) intrinsic (Ae) extrinsic | ml/g ml/m2 | 6.7 396 | IEST-RP-CC004.3 | |
NVR Non-volatile residues |
IPA based DI water based |
g/m2 g/m2 |
0.028 0.038 | IEST-RP-CC004.3 |
Particulate residues |
0.5 – ≤ 5.0 µm > 5.0 – ≤ 100 µm |
x 106/m2 x 106/m2 |
140 9.9 |
IEST-RP-CC004.3 Section 6.1.3 Biaxial Shake Test |
Fibre residues | > 100 µm | fibres/m2 | 154,778 |
IEST-RP-CC004.3 Section 6.2.2.2 |
Ionic residues |
Sodium (Na+) Chloride (ClO2-) |
ppm ppm |
70 42 |
IEST-RP-CC004.3 Section 7.2.2.1 |
Sterilisation | validated sterile |
Sterility Assurance Level (SAL) | 10-6 | AAMI / ISO 11137 |
Organic contaminants |
silicone oil amides D-n-octylphthalate (DOP) |
n. s. n. s. n. s. |
by FTIR spectrometer Fourier transform infrared spectrometer | |
Size | PU/Carton | subpacked | Art. No. | |
4" x 4" 9" x 9" 12" x 12" 18" x 18" |
on request 150 (6 x 25) 150 (6 x 25) 75 (3 x 25) |
12 x 150 wipes (6 x 25 wipes) 7 x 150 wipes (6 x 25 wipes) 5 x 75 wipes (3 x 25 wipes) |
57300 0404 57300 0909 57300 1212 57300 1818 | |
n. s. = not specified n. d. = not detectable |
Note