The validated sterile wipes PROSAT® PSC20005 made of hydroentangled cellulose-polyester non-woven fabric are saturated with 70 % IPA / 30 % DI water (USP quality). They are especially suitable for a range of cleaning tasks in areas where validated sterility is required. The reclosable pouch maintains solvent saturation and cleanliness.
Facts
Saturated wipes
Non-woven, 46% PES / 54% CEL, with 70% IPA / 30% DI water, validated sterile
Properties
- 46% polyester/54% cellulose
- non-woven fabric made of water jet entangled staple fibres
- saturated with 70% IPA/30% DI water (USP quality)
- validated sterile (SAL of 10-6)
- reclosable PE pouch, packed in an outer bag
Advantages
- reduced level of volatile organic compounds (VOC)
- fast and efficient cleaning
- reduces the storage of cleaning agents
- easier to transport, store and use
- even application of the cleaning solution
Application
- wiping of objects before the airlock procedure
- for quick and practical surface cleaning of equipment and parts
- wet cleaning of scratch-sensitive surfaces to specifically remove chemical residues
Product recommendation based on cleanroom classes
Of course, cleanroom wipes used in ISO 5 can also be used in ISO 9, but in this case the economic efficiency and usefulness should be considered.
A 1 to 1 allocation of cleanroom wipes to an air cleanliness class according to ISO 14644-1 is not possible. Recommendations can only be made on the basis of special properties relevant from a cleanroom technical point of view, such as "abrasion resistance" or "particle emission". Users can find further information on this in VDI Guideline 2083 Part 9.2.
Technical data
Properties | Unit of measurement | Value | Test method | |
---|---|---|---|---|
Material (fabric) | 54% CEL / 46% PES | |||
Saturation solution | 70% IPA (USP grade) / 30% DI water | |||
Edge processing | cut | |||
Mass per unit area | g/m2 | 53 | manufacturer's specific | |
NVR non-volatile residues) |
IPA based DI water based |
g/m² g/m² |
not detected* 0.037 |
IEST-RP-CC004.3, Sec. 7.1.2 IEST-RP-CC004.3, Sec. 7.1.2 |
Particle residues | ≥ 0,5 µm | x 106/m2 | 18.6 | IEST-RP-CC004.2, Sec 5.1 |
Fibre residues | > 100 µm | x 103/m2 | 21.7 | IEST-RP-CC004.2, Sec. 5.2 |
Ionic residues |
Sodium (Na+) Chloride (ClO2-) |
ppm ppm |
11.9 18.2 |
IEST-RP-CC004.3, Sec. 7.2.2 IEST-RP-CC004.3, Sec. 7.2.2 |
Sterilisation |
validated sterile per gamma irradiation | SAL (10-6) | yes | n.s. |
Dimensions | PU per carton | Art. no. | ||
9" x 11" (~ 23 x 28 cm) |
1,400 pieces (50 pcs./Pouch) double bagged | 59808 | ||
* Levels are below detection limit of test equipment |