Series 425, a microfibre wipe made of 70% polyester and 30% nylon is knitted from filaments. Due to their microfibre structure, these wipes are among the most efficient cleaning wipes and can also easily remove greasy stains (such as fingerprints). They are used in microbiological controlled areas as well as in purely particle controlled areas. The wipes are cut by laser, thus sealing the wipe edges. After cutting, the wipes are professionally decontaminated in a cleanroom laundry and packed under ISO 4 conditions (EN ISO 14644-1). The wipes, even if they are made of pure synthetic fibres, have a good absorption capacity. The robust microfibre cloth of these wipes shows its strength especially on sensitive surfaces (optical devices, screens, etc.). Due to the cleanroom-compatible post-process decontamination, the wipes have relatively low levels of ionic and metallic contamination. 

The series 425 is also available in a sterile version.

Facts

Particle emission (dry)
Particle emission (wet)
Abrasion resistance
Wet cleaning
Dry cleaning
Chemical permanence
Electrostatic behaviour
Softness
Sealed edges
decontaminated
sterile

Special requirements

Series 425

Microfibre knit, 70% PES/30% nylon, laser-sealed edges

-

Properties

  • 70% polyester / 30% nylon
  • knitted fabric made from microfibres
  • edges cut and sealed by laser
  • low particle and fibre emission
  • abrasion resistant
  • decontaminated in a cleanroom laundry
  • double bag packed in a cleanroom (air cleanliness class ISO 4)

Advantages

  • wipe with very high cleaning efficiency
  • reduced particle and fibre emission due to the sealed edges
  • very wide range of applications
  • low ionic and metallic impurities
  • soft surface and therefore also suitable for scratch-sensitive surfaces
  • also available in a sterile version

Applications

  • cleaning wipe especially for critical areas
  • cleaning wipe for all other areas
  • well suited for sharp-edged, rough surfaces and objects that might prematurely damage a non-woven wipe

Product recommen­dation based on cleanroom classes


123456789low dust


ABCDE

Of course, cleanroom wipes used in ISO 5 can also be used in ISO 9, but in this case the economic efficiency and usefulness should be considered.

A 1 to 1 allocation of cleanroom wipes to an air cleanliness class according to ISO 14644-1 is not possible. Recommendations can only be made on the basis of special properties relevant from a cleanroom technical point of view, such as "abrasion resistance" or "particle emission". Users can find further information on this in VDI Guideline 2083 Part 9.2.

Technical data

Properties   Unit of measurementValueTest method
Material     70% PES / 30% PA 6.6  
Edge processing     laser cut  
Mass per unit area   g/m2 ± 10% 190  
Absorption capacity
(Ai) intrinsic
(Ae) extrinsic
 
ml/g
ml/m2

n. s.
360
IEST-RP-CC004.3
NVR
Non-volatile residues
IPA based
DI water based
g/m2
g/m2
0.12
0.03
IEST-RP-CC004.3
Particle residues > 0.5 µm - 2,0 µm x 106/m2 15 IEST-RP-CC004.3
Section 6.1.4 Orbital shake test
Fibre residues ≥ 100 µm count/m2 95 IEST-RP-CC004.3
Ionic residues Chloride (ClO2-)
Nitrate (NO3-)
Potassium (K+)
Sodium (Na+)
Sulphate (SO42-)
µg/g
µg/g
µg/g
µg/g
µg/g
0.50
0.50
0.20
1.00
0.20
IEST-RP-CC004.3
Organic contaminants silicone oil
amides
D-n-octylphthalate (DOP)
  n. s.
n. s.
n. s.
by FTIR spectrometer
Fourier transform infrared spectrometer
  SizePU/CartonsubpackedArt. No.
  4" x 4"
6" x 6"
9" x 9"
12" x 12"
12" x 16"
± 0,2"/0,5 cm
4,000
3,000
1,000
1,000
800
10 bags à 400 wipes
20 bags à 150 wipes
10 bags à 100 wipes
20 bags à 50 wipes
40 bags à 20 wipes
55425 0404
55425 0606
55425 0909
55425 1212
55425 1216
      n. s. = not specified
n. d. = not detectable
 

Note

The manufacturer's technical data listed above are typical values at the time of publication. They are not specifications. All data are without guarantee, changes are possible without prior notice.
Due to different test methods depending on the respective manufacturers and test laboratories, most of the given values cannot be compared one-to-one with those of other manufacturers/wipes.
Independent tests can be commissioned on request.

To top