+++ 04.11.2024 - 11:21 Uhr: The sales units for selected products will be optimised shortly. If you have any questions about this, please call your contact person in the sales department. +++

Skip to main content

Clino® One Way Profi

Wipe for special requirements

Back to our wipes for special requirements

The Clino® One Way Profi disposable wipe, a microfibre wipe made of polyester and polyamide (80%/20%), is characterised by very good cleaning performance, even with greasy dirt. Even though it is made of purely synthetic fibres, the wipe has a sufficient absorption capacity for aqueous solutions. The chemical resistance is given with acids (peracetic acid), alkalis (caustic soda, nitric acid), bleaching agents, solvents (isopropanol, acetone, benzene compounds). The wipes are primarily used in areas that are controlled purely by particles, but can also be used at any time in microbiological controlled zones. The cutting is done by ultrasound and thus the edges are sealed. After cutting, the wipes are professionally decontaminated in a cleanroom laundry and packed under ISO class 5 conditions. Due to the cleanroom-compatible post-cleaning, the wipes have relatively low levels of ionic and metallic contamination.

Facts

Particle emission (dry)
Particle emission (wet)
Abrasion resistance
Wet cleaning
Dry cleaning
Chemical permanence
Electrostatic behaviour
Softness
Sealed edges
decontaminated
sterile

Special requirements

Clino® One Way Profi

Microfibre wipe, woven, 80% PES / 20% PA

-

Properties

  • 80% polyester / 20% polyamide
  • woven from microfibre filaments
  • ultrasonically cut and sealed edges
  • decontaminated in a cleanroom laundry
  • vacuum-packed twice in PE film in a cleanroom

Advantages

  • very good cleaning performance due to the elastic and dense weave and the structured surface
  • low abrasion even under heavy mechanical load
  • high chemical resistance and low abrasion due to the twisted threads

Applications

  • effective removal of particulate and organic contamination
  • very well suited for wiping highly sensitive surfaces

Product recommen­dation based on cleanroom classes


123456789low dust


ABCDE

Of course, cleanroom wipes used in ISO 5 can also be used in ISO 9, but in this case the economic efficiency and usefulness should be considered.

A 1 to 1 allocation of cleanroom wipes to an air cleanliness class according to ISO 14644-1 is not possible. Recommendations can only be made on the basis of special properties relevant from a cleanroom technical point of view, such as "abrasion resistance" or "particle emission". Users can find further information on this in VDI Guideline 2083 Part 9.2.

Technical data

Properties   Unit of measurementValueTest method
Material     80% PES / 20% PA  
Edge processing     ultrasonic cut  
Mass per unit area   g/m2 100 ± 5 ASTM D3776
Standard Test Methods for Mass Per Unit Area (Weight) of FabricISO 9073
Weight (wipe)   g 9.29 ASTM D3776
Thickness   mm 0.22 ± 0.02 ASTM D1777
Standard Test Method for Thickness of Textile MaterialsISO 9073-2
Textiles – Test methods for nonwovens – Part 2: Determination of thickness
Absorptive capacity
Ai intrinsic
Ae extrinsic
 
ml/g
ml/m2

n. s.
200
IEST-RP-CC004.3
Section 8.2
Absorbency rate   sec. < 5 IEST-RP-CC004.3
Section 8.2
NVR
Non-volatile residues
IPA based
DI water based
g/m2
g/m2
< 1.5
< 0.8
IEST-RP-CC004.3
Section 7
Particulate residues > 0.5 µm particles/wipe < 100 IEST-RP-CC003.4
Fibre residues > 100 fibres/m2< 500 IEST-RP-CC003.4
Organic substances   µg/g or ppm not detectable IEST-RP-CC004.3
Section 7
Ionic residues Chloride (ClO2-)
Nitrite (NO2-)
Sodium (Na+)
Sulphate (SO42-)
µg/g
µg/g
µg/g
µg/g
< 4
< 4
< 4
< 4
IEST-RP-CC004.3
Section 7
Organic contaminants silicone oil
amides
D-n-octylphthalate (DOP)
  n. s.
n. s.
n. s.
by FTIR spectrometer
Fourier transform infrared spectrometer
  SizePU/CartonsubpackedArt. No.
  12" x 12"
(30,48 x 30,48 cm)
1,500 10 bags à 150 wipes 55429
      n. s. = not specified
n. d. = not detectable
 

Note

The manufacturer's technical data listed above are typical values at the time of publication. They are not specifications. All data are without guarantee, changes are possible without prior notice.
Due to different test methods depending on the respective manufacturers and test laboratories, most of the given values cannot be compared one-to-one with those of other manufacturers/wipes.
Independent tests can be commissioned on request.

To top