Facts
Show comparison list
Nitrile
Material: Nitrile
Properties
- 100% nitrile
- powder-free
- packed in bags
- ambidextrous
Advantages
- good surface cleanliness
- high clearance of ions
- conductive / ESD compliant
- high permeation time for chemicals
- extra long, 40 cm
Application
- for high process requirements
- for working with chemicals
- for heavy mechanical stress
Product recommendation based on cleanroom classes
Air cleanliness class EN ISO 14644-1
particulate monitored areas
Hygiene zones according to GMP
microbiological monitored areas
PPE
Personal protective equipment
Regulation (EU) 2016/425
A one-to-one classification of cleanroom gloves to a cleanroom class according to ISO 14644-1 is not possible. Recommendations can only be made based on cleanroom specific requirements, e.g. "abrasion resistance" or "particle emission". In the VDI guideline 2083 Part 9.2 the user can find additional information.
Technical data
Unit of measurement | Value | Test method | ||
Material | 100% nitrile | |||
Perforation free1 AQL value as defined in ISO 2859-1 for attribute testing on samples | AQL1 | 1.5 Level 2 | ISO 374-2:2019 | |
Tear resistance |
before ageing after accelerated ageing | N min./typical |
6.0/7.0 6.0/8.0 |
EN 455-2:2015 + ASTM D412-15a ASTM D573-04(2015) |
Extreme elongation |
before ageing after accelerated ageing |
% min. |
500 400 |
EN 455-2:2015 + ASTM D412-15a ASTM D573-04(2015) |
Dimensions nominal single wall thickness |
middle finger palm cuff | mm |
0.20 0.15 0.10 | ASTM D3767-03(2014) |
Length | mm min./typical | 385/400 | EN ISO 21420:2020 | |
Size/palm size nominal |
XS / 6 S / 7 M / 8 L / 9 XL / 10 XXL / 11 | mm |
≤ 80 85 95 105 115 ≥ 120 | EN 455-2:2015 |
Size/Hand circumference nominal |
XS / 6 S / 7 M / 8 L / 9 XL / 10 XXL / 11 | mm |
152 178 203 229 254 279 | EN ISO 21420:2020 |
Extractable particles | ≥ 0.5 µm |
fixed typical number/cm2 | < 1,200 950 | IEST-RP-CC005.4 |
Endotoxins detected by LAL test, kinetic turbidimetric |
Endotoxin units (EU) per pair | < 20 | EN 455-3:2015 | |
Silicones, amides, Di-n-octylphthalate (DNOP) | not detectable | |||
Powder-free on the surface | µg/gloves |
approx. 1.0 – max. 2.0 | ISO 21171:2006 | |
Biocompatibility | certified |
Modified epicutaneous test according to Buehler + Primary Skin Irritation Tests | ||
Chemical allergens | not detectable |
HPLC test method for qualitative analysis + aqueous phosphate solution extraction | ||
Non volatile residues (NVR) | µg/g | max. 30 | IEST-RP-CC005.4 | |
Extractable substances | Ions Ammonium (NH4+) Bromide (Br-) Calcium (Ca+) Chloride (ClO2-) Copper (Cu+) Fluoride (F-) Iron (Fe+) Lithium (Li+) Magnesium (Mg+) Nitrate (NO3-) Nitrite (NO2-) Phosphate (PO43-) Potassium (K+) Sodium (Na+) Sulphate (SO42-) Zinc (Zn+) |
µg/cm2 specification 0.050 0.030 0.200 0.200 n.s. 0.010 n.s. n.s. 0.010 0.200 0.050 0.050 0.050 0.050 0.050 n.s. |
µg/cm2 typical value 0.017 <0.008 0.160 0.110 n.s. <0.008 n.s. n.s. <0.008 0.130 <0.008 <0.008 0.020 0.020 0.020 n.s. | IEST-RP-CC005.4 |
Surface resistance | Ω/sq. | 108-1010 | ASTM D257-14 | |
ESD properties surface resistance contact resistance charge decay electrostatic properties (design + material requirements) |
tested | EN 1149-1:2006 EN 1149-2:1997 EN 1149-3:2004 EN 1149-5 | ||
PU |
100 pieces flat packed in PE inner bag | |||
Cardboard quantity |
1,000 pieces 10 PE bags of 100 pieces in PE outer bags |