Facts


Show comparison list
Surface cleanliness
Grip
Elongation
Endotoxin pollution
Ion-free
Cytostatics compatible
Chemical protection
sterile
textured
hand specific

Latex

Kimtech™ G3 Latex, Art.-No. 3503

Material: Latex

Properties

  • 100% latex
  • powder-free, silicone-free
  • packed in bags
  • ambidextrous

    Advantages

    • satisfactory surface cleanliness
    • very good form fit
    • very high elasticity
    • very high tear resistance
    • good grip

    Application

    • for normal process requirements
    • for heavy mechanical stress

    Product recommen­dation based on cleanroom classes

    Air cleanliness class EN ISO 14644-1
    particulate monitored areas

    123456789low dust

    Hygiene zones according to GMP
    microbiological monitored areas

    ABCDE

    PPE

    Personal protective equipment
    Regulation (EU) 2016/425

    Cat. ICat. IICat. IIInot aplicable

    A one-to-one classification of cleanroom gloves to a cleanroom class according to ISO 14644-1 is not possible. Recommendations can only be made based on cleanroom specific requirements, e.g. "abrasion resistance" or "particle emission". In the VDI guideline 2083 Part 9.2 the user can find additional information.

    Technical data

        Unit of measurementValueTest method
    Material     100% Latex  
    Perforation free1
    AQL value as defined in ISO 2859-1
    for attribute testing on samples
      AQL1 1.5 ASTM D5151 + EN 374-2
    Tear resistance before ageing
    after accelerated ageing
    MPa, nominal 28
    27
    ASTM D412 + ASTM D573
    Extreme extensibility before ageing
    after accelerated ageing
    %, nominal
    845
    895
    ASTM D412 + ASTM D573
    Dimensions
    nominal single wall thickness
    middle finger
    palm
    cuff
    mm 0.22
    0.20
    0.15
    ASTM D3767, ASTM D6319 + EN ISO 21420:2020
    Length   mm 305  
    Size/palm width
    S
    M
    L
    XL
    mm 85
    96
    109
    118
    ASTM D3767, ASTM D6319 + EN ISO 21420:2020
    Biocompatibility     n.s. Primary Skin Irritation Tests +
    Dermal Sensitization Test
    according to ASTM F720-13
    Extractable particles > 0.5 µm number/cm2 max. 1,500 IEST-RP-CC005
    Extractable substances
    Ions

    Ammonium (NH4+)
    Bromide (Br-)
    Calcium (Ca+)
    Chloride (ClO2-)
    Copper (Cu+)
    Fluoride (F-)
    Iron (Fe+)
    Lithium (Li+)
    Magnesium (Mg+)
    Nitrate (NO3-)
    Nitrite (NO2-)
    Phosphate (PO43-)
    Potassium (K+)
    Sodium (Na+)
    Sulphate (SO42-)
    Zinc (Zn+)
    µg/g
    specification
    10
    n.s.
    20
    100
    n.s.
    n.s.
    n.s.
    n.s.
    5
    15
    n.s.
    n.s.
    0.03
    25
    25
    90
    µg/cm2
    typical value
    0.07
    n.s.
    0.13
    0.67
    n.s.
    n.s.
    n.s.
    n.s.
    0.03
    0.10
    n.s.
    n.s.
    0.03
    0.16
    0.17
    0.60
    IEST-RP-CC005.4
    Non volatile residues (NVR)   mg/g n.s. IEST-RP-CC005.4
    Aqueous extractable
    proteins in latex
      µg/g max. 50 ASTM D5712 + EN ISO 21420:2020
    Endotoxins (maximum) Endotoxin units (EU) per pair n.s. Kinetic turbidimetric
    LAL test method
    ESD behaviour
    Surface resistance
    Transit resistance
    Charges depletion
    Electrostatic properties
    (construction + material requirements)
      n.s.
     
    EN 1149-1:2006
    EN 1149-2:1997
    EN 1149-3:2004
    EN 1149-5
    Carton quantity     1,000 pieces
    10 bags of 100 pieces
    in a big bag
     

    The manufacturer's technical data listed above are typical values at the time of publication. They are not specifications. All data are without guarantee, changes are possible without prior notice.

    To top