Facts
Show comparison list
Nitrile-polychloroprene mixture
Material: Nitrile-polychloroprene mixture
Properties
- nitrile / polychloroprene mixture
- powder-free
- packed in boxes
- ambidextrous
Advantages
- adequate surface cleanliness
- high permeation time for chemicals
- good grip
- high ductility
Application
- for laboratory requirements
- for working with chemicals
Product recommendation based on cleanroom classes
Air cleanliness class EN ISO 14644-1
particulate monitored areas
Hygiene zones according to GMP
microbiological monitored areas
PPE
Personal protective equipment
Regulation (EU) 2016/425
A one-to-one classification of cleanroom gloves to a cleanroom class according to ISO 14644-1 is not possible. Recommendations can only be made based on cleanroom specific requirements, e.g. "abrasion resistance" or "particle emission". In the VDI guideline 2083 Part 9.2 the user can find additional information.
Technical data
Unit of measurement | Value | Test method | ||
Material Outer layer/inner layer |
nitrile/polychloroprene orange/white | |||
Perforation-free1 AQL value as defined in ISO 2859-1 for attribute testing on samples | AQL1 | 0.25 Level 3 | EN 374-2:2019 | |
Tear resistance |
before ageing after accelerated ageing | N min./typical |
6.0/10.0 6.0 8.0 |
EN 455-2:2015 ASTM D573-04(2019) |
Extreme elongation |
before ageing after accelerated ageing |
% min. |
≥ 500 ≥ 400 |
EN 455-2:2015 ASTM D573-04(2019) |
Dimensions nominal single wall thickness |
middle finger palm cuff | mm |
0.17 0.14 0.10 | ASTM D3767-03(2020) |
Length | mm min./typical | 260/265 | EN 455-2:2015 | |
Size/palm width nominal (+/- 5 mm) |
XS / 6 S / 7 M / 8 L / 9 XL / 10 | mm |
≤ 80 85 95 105 ≤ 110 | EN 455-2:2015 |
Size/Hand circumference nominal |
XS / 6 S / 7 M / 8 L / 9 XL / 10 | mm |
152 178 203 229 254 | EN 455-2:2015 |
Biocompatibility | certified |
ISO 10993-10 - 2010-08 Tests for irritation and skin sensitization | ||
Powder residue values |
mg/gloves typical (max.) |
powder-free ≤ 1.0 (max. 2.0) | ISO 21171:2006 | |
Extractable particles | ≥ 0.5 µm |
fixed typical number/cm2 |
n.s. n.s. | IEST-RP-CC005.4 |
Extractable substances | Ions Ammonium (NH4+) Bromide (Br-) Calcium (Ca+) Chloride (ClO2-) Copper (Cu+) Fluoride (F-) Iron (Fe+) Lithium (Li+) Magnesium (Mg+) Nitrate (NO3-) Nitrite (NO2-) Phosphate (PO43-) Potassium (K+) Sodium (Na+) Sulphate (SO42-) Zinc (Zn+) |
µm/cm2 specification n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. |
µm/cm2 typical value n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. | IEST-RP-CC005.4 |
Non volatile residues (NVR) | mg/g | n.s. | IEST-RP-CC005.4 | |
ESD behaviour surface resistance contact resistance charge decay electrostatic properties (construction + material requirements) |
tested | EN 1149-1:2006 EN 1149-2:1997 EN 1149-3:2004 EN 1149-5 | ||
Permeation resistance of medical gloves for chemotherapeutics | tested | ASTM D6978-05(2019) | ||
PU |
90 piece flat packed in carton dispenser (inner box) | |||
Carton quantity |
900 pieces 10 carton dispensers |