Facts
Show comparison list
Latex
Material: Latex
Properties
- 100% latex
- powder-free
- packed in boxes
- ambidextrous
Advantages
- adequate surface cleanliness
- very good form fit
- good grip
- very high elasticity
Application
- for laboratory requirements
- when a high level of sensitivity is required
Product recommendation based on cleanroom classes
Air cleanliness class EN ISO 14644-1
particulate monitored areas
Hygiene zones according to GMP
microbiological monitored areas
PPE
Personal protective equipment
Regulation (EU) 2016/425
A one-to-one classification of cleanroom gloves to a cleanroom class according to ISO 14644-1 is not possible. Recommendations can only be made based on cleanroom specific requirements, e.g. "abrasion resistance" or "particle emission". In the VDI guideline 2083 Part 9.2 the user can find additional information.
Technical data
Unit of measurement | Value | Test method | ||
Material | 100% Latex (NR) | |||
Perforation-free1 AQL value as defined in ISO 2859-1 for attribute testing on samples | AQL1 | 1.5 | EN 455-1:2000 + EN 374-2:2014 | |
Tear resistance |
before ageing after accelerated ageing | MPa, specific |
18 14 |
EN 455-2:2015 + ASTM D412-16 ASTM D573-04(2015) |
Extreme extensibility |
before ageing after accelerated ageing |
%, specific |
≥ 700 ≥ 500 |
EN 455-2:2015 + ASTM D412-16 ASTM D573-04(2015) |
Dimensions nominal single wall thickness |
middle finger hand surface cuff | mm |
0.18 0.14 0.12 | ASTM D3767 + ASTM D3577 |
Length tip middle finger to end cuff |
mm typical |
240 242 |
EN ISO 21420:2020 + EN 455-2:2015 | |
Size/palm width nominal |
XS/6 S/7 M/8 L/9 XL/10 | mm |
≤ 80 85 95 105 ≥ 110 | EN 455-2:2015 |
Extractable particles | ≥ 0.5 µm |
specific typical number/cm2 |
n.s. | IEST-RP-CC005.2 |
Extractable substances | Ions Ammonium (NH4+) Bromide (Br-) Calcium (Ca+) Chloride (ClO2-) Copper (Cu+) Fluoride (F-) Iron (Fe+) Lithium (Li+) Magnesium (Mg+) Nitrate (NO3-) Nitrite (NO2-) Phosphate (PO43-) Potassium (K+) Sodium (Na+) Sulphate (SO42-) Zinc (Zn+) |
µm/cm2 specification n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. |
µm/cm2 typical value n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. n.s. | IEST-RP-CC005.4 |
Biocompatibility | certified |
ISO 10993-10:2010 Tests for irritation and skin sensitization | ||
Powder residue values |
mg/gloves typical (max.) |
powder-free ≤ 1.0 (max. 2.0) | ISO 21171:2006 | |
Glove-related allergies sensitisation of water-soluble natural latex proteins (type 1 allergy) |
µg/g specific µg/g typical | < 50 < 30 |
EN 455-3:2015 + ASTM D5712-15 Modified Lowry Method | |
Non Volatile Residues (NVR) | mg/g | n.s. | IEST-RP-CC005.4 | |
Endotoxins (maximum) |
Endotoxin units (EU)per pair | n.s. |
Kinetic turbidimetric LAL test method | |
Surface Resistance | Ω/sq. | n.s. | ASTM D257-14 | |
PU |
100 pieces flat packed in a carton dispenser (inner box) | |||
Carton quantity |
1.000 pieces 10 carton dispenser |