The sterile version of series 415, a 100% polyester wipe knitted from filaments, belongs to the classic cleanroom cleaning wipes for more critical areas, both in microbiological controlled and in only particle-controlled zones. After the edges are cut by laser, the wipes are professionally decontaminated in a cleanroom laundry and packaged under ISO 4 conditions (EN ISO 14644-1). Even though they are made of 100% polyester, the wipes have a decent absorption capacity.
The robust polyester knitted fabric shows its strength on rougher surfaces or with sharp-edged objects and/or surfaces. Due to the cleanroom-compatible decontamination, the wipes have relatively low levels of ionic and metallic contaminants. In addition, there is a low load of non-volatile residues (NVR) and good chemical resistance.
Feiten en cijfers
Polyester
Knit, 100% PES, 145 g/m², laser sealed edges
Properties
- 100% polyester
- knitted fabric made of filaments
- sterile
- low particle and fibre emission
- abrasion resistant
- decontaminated in a cleanroom laundry
- double bag packed in a cleanroom (air cleanliness class ISO 4)
Advantages
- robust wipe
- reduced particle and fibre emission due to the sealed edges
- very wide range of applications
- low ionic and metallic impurities
Applications
- cleaning wipe for critical and non-critical areas
- well suited for angular, rough surfaces and objects that might prematurely damage a non-woven fabric wipe
Product recommendation based on cleanroom classes
Of course, cleanroom wipes used in ISO 5 can also be used in ISO 9, but in this case the economic efficiency and usefulness should be considered.
A 1 to 1 allocation of cleanroom wipes to an air cleanliness class according to ISO 14644-1 is not possible. Recommendations can only be made on the basis of special properties relevant from a cleanroom technical point of view, such as "abrasion resistance" or "particle emission". Users can find further information on this in VDI Guideline 2083 Part 9.2.
Technical data
Properties | Unit of measurement | Value | Test method | |
---|---|---|---|---|
Material | 100% PES | |||
Edge processing | laser cut | |||
Mass per unit area |
± 10 g/m2 | 145 | ||
Absorptive capacity (Ai) intrinsic (Ae) extrinsic | ml/g ml/m2 | 3.0 400 | IEST-RP-CC004.3 | |
NVR Non-volatile residues |
IPA based DI water based |
g/m2 g/m2 |
0.015 0.004 | IEST-RP-CC004.3 |
Absorbency rate | second | < 1 | IEST-RP-CC004.3 | |
Particulate residues | > 0,5 µm – ≤ 100 µm | x 106/m2 | 3.0 |
IEST-RP-CC004.3, Sec. 6.1.4 Orbital shake test) |
Fibre residues | > 100 µm | fibres/m2 | 200 | IEST-RP-CC004.3 |
Ionic residues |
Chloride (ClO2-) Sodium (Na+) Sulphate (SO42-) |
µg/g µg/g µg/g |
0.10 0.15 0.08 | IEST-RP-CC004.3 |
Organic contaminants |
silicone oil amides D-n-octylphthalate (DOP) |
n. s. n. s. n. s. |
by FTIR spectrometer Fourier transform infrared spectrometer | |
Sterilisation | Gamma irradiation | kGy | 25 – 40 | DIN EN ISO 11137-1 |
Size | PU/Carton | subpacked | Art. No. | |
Gamma irradiated |
9" x 9" 12" x 12" |
1,500 1,000 |
150 bags à 10 wipes 100 bags à 10 wipes |
57415 0909 57415 1212 |
n. s. = not specified n. d. = not detectable |
Note